Effect of Initial pH The removal efficiency of TCH showed a trend of initial increase followed by a subsequent decrease with varying pH levels, as shown in Figure 9 .
Excerpts
a clear trendgold
Influence of Initial Solution Concentration The experimental results of Sb(III) adsorption by FM@GC are plotted under experimental conditions with different initial Sb(III) concentrations ( C 0 = 5 to 700 mg/L) Figure 2 c shows that the curves of removal efficiency ( R e ) and equilibrium adsorption capacity ( Q e ) exhibit a clear trend with increasing initial concentration.
Even when qualitatively mimicking non-specific solvent effects, departures of calculated values from experimental data may be significant (20–30%).
Some of the chlorine atoms of the CH 2 Cl 2 solvent molecules also have long interactions with some hydrogen atoms: they range from 2.94 to 3.15 Å, though these are probably of marginal significance.
The model’s F -value of 210.61 ( p < 0.0001) indicates that it is highly significant and a strong predictor of the ABP yield.
The model had a highly significant F value of 11.75, with a p value less than 0.0001.
Compared with SD samples, with the temperature increase, the content of amino acids showed a trend of first decreasing and then increasing, while the content trend of proteins was the opposite.
The delivery systems differ in physical and chemical properties, but a significant trend of utilizing nanotechnology is noticeable in the majority of the selected studies.
a notable trendgold
Although de/hydrogenation reactions are essential for the development of the LOHC technology, an analysis of the temporal evolution of concepts related to those reactions (see Figure 5 ) revealed a notable trend.
All the SWE extracts showed a trend that is globally greater than that of the other extraction techniques ( Table S2b ), except for flavonoids, which, extracted with 100% water, are subject to degradation as the temperatures increase [ 52 ]; due to this, they have not been detected (4SWE, 5SWE, and 6SWE).
As the electric strength increased, the positive relative change rate of α-D-glucose generally showed an increasing trend by up to 3.25%.
According to the ANOVA table ( Table 2 ), the very low p -value (<0.0001) indicates that the regression model is highly significant, explaining a substantial portion of the variability in the data.
In the model, the first-order terms A, C and their interaction term BC, as well as the second-order terms (A 2 ), (B 2 ), and (C 2 ), all have a highly significant effect on the polysaccharide extraction rate.
In turn, p values between 0.05 and 0.1 were considered to indicate a statistical trend.
Molecular docking analysis and IC 50 values from in vitro urease inhibition screening showed a trend of increasing activity from compounds 7d to 7c to 7b .
At the same time, the remaining samples exhibited a decreasing trend.
an obvious trendgold
Simultaneously, an obvious trend indicating a reduction in transmission peak intensity with increasing A-INDO content is observed in Figure 6 B, providing an opportunity for quantitative analysis of A-INDO using NIR spectroscopy.
Meanwhile, decarboxylation, as a side reaction, is highly significant and contributes to a decrease in H 2 purity.
edulis , showing a highly significant correlation with them (see Figure 3 ).
However, the γ-PGA recovery showed a decreasing trend with increasing decolorization time.
The omnibus multivariate test showed that the influence of the type of producer was barely statistically significant (only according to Roy’s multivariate criterion), while there was no statistical significance for any of the differences between years.
Results with significance levels between 0.05 < p < 0.09 were considered significant at the level of a statistical trend. 4.
In our case, the SGC content showed an increasing trend from the upper part of the core to the interface between mesotelm and acrotelm.
Three distinct patterns are evident: (a) the highest carbon output, at the top most depth sample; (b) a decreasing trend from the top vegetation layer to the base of the mesotelm (dropping from 26% to 21% between Acro-Bot and Meso, as shown in Table 1 ); (c) and a plateau at the core’s lower depths (%C stabilizing around 38% between Int_Meso-Cato and Cato).
Additionally, as verified by the data in Table 1 , both the O/C ratio and H/C ratio exhibit a decreasing trend with increasing pyrolysis temperature.